Glossary of Magnetic Terms

Air Gap

A non-magnetic discontinuity in a magnetic circuit (i.e. the distance between two magnetic poles), this gap often includes other materials such as brass, aluminium or paint.

Anisotropic Magnet

A magnet which has a preferred direction of orientation so that the magnetic characteristics are optimum in one preferred direction.

Closed Circuit

This exists when the flux path external to the permanent magnet is confined within high permeability materials which contain the magnet circuit.

Coercive Force, Hc

The demagnetizing force necessary to reduce observed induction B to zero after the magnet has been brought to saturation. Coercive force is measured in Oersteds or more recently A/m and kA/m.

Curie Temperature, Tc

The temperature at which a material loses its permanent magnetic properties completely and is no longer able to hold magnetism.

Demagnetisation Curve

The second/left quadrant of the hysteresis loop, generally describing the behaviour of magnetic characteristics in actual use. Also known as the B-H curve.

Ferromagnetic Material

A material whose permeability is very much larger than one, and which exhibits hysteresis magnetizing and demagnetizing characteristics. The greater the flux carrying potential, the bigger the value i.e. one to several thousands.

Flux

Magnetic flux is the condition existing in a medium subjected to a magnetizing force. This value is quantified by E.M.F. (electromotive force). This measurement of force in cgs units is a Maxwell.

Fringing Fields

Leakage flux particularly associated with edge effects and leakage patterns in a magnetic circuit.

Gauss

Lines of magnetic flux per square centimetre. Gauss is measured in cgs units, Maxwell lines and Webers per square metre or Tesla in the Si system.

Hysteresis Loop

A closed curve calculated by plotting corresponding values of magnetic induction: B on the abscissa against magnetising force H.

Induction, B

This is the magnetic flux per unit area of section in the applied magnetic direction of flux. This is measured in Gauss.

Intrinsic Coercive Force

This is a measure of the resistance of the magnet material to a demagnetizing force. Permanent magnets with high intrinsic coercivity values are usually classified as 'hard' permanent magnets. Intrinsic coercive force indicates magnetic stability at high temperatures. Also see stabilization.

Irreversible Loss

This is the partial demagnetization of a magnet material when introduced to external factors such as high/low temperatures and demagnetizing fields. Losses can only by rectified by remagnetization. However, magnets can be stabilized to prevent the variation of performance caused by irreversible losses.

Isotropic Magnet

A magnetic material which does not have a preferred direction of magnetic orientation and therefore can be magnetized in any direction without the loss of magnetic characteristics.

Knee of the Demagnetisation Curve

The point at which the B-H curve ceases to be linear. If the operating point of the magnet falls below the knee, the magnet will not be able to recover full magnetic potential without the application of a magnetizing force.

Leakage Flux

This is the loss of magnetic flux which occurs through leakage caused by saturation or air gaps introduced into the magnetic circuit. This induces a loss of efficiency in the circuit which cannot be recovered.

Length of Air Gap, Lg

Indicates the length of the central flux path across an air gap.

Load Line

A line drawn from the origin of the Demagnetization Curve with a slope. The intersection of the -B/H curve and slope represents the operating point of the magnet. Also see Permeance Coefficient, Pc.

Magnetic Circuit

An assembly consisting of some or all of the following: permanent magnets, ferromagnetic conduction elements, air gaps, electrical currents.

Magnetic Flux

The total magnetic induction over a given area.

Magnetising Force, H

The magnetomotive force per unit length at any point in a magnetic circuit. This is measured in Oersteds.

Magnetomotive Force, F

This is the potential magnetic difference between any two points.

Maximum Energy Product, BH max.

There is a point at the Hysteresis Loop at which the product of magnetizing force H and induction B reaches a maximum. This maximum value is called the Maximum Energy Product and is measured in Mega Gauss Oersted, MGOe.

Oersted, Oe

A unit measure of magnetizing force (cgs). This is equivalent to Ampere Turns per Inch (S.I.).

Permeance Coefficient, Pc

Ratio of the magnetic induction to self demagnetizing force. This is also known as the 'load line' or operating point of the magnet.

Pull Gap

Usually illustrated in graph format, these curves are a representation of the relationship between the attractive force exerted by a magnet on a soft magnetic workpiece and the distance between them. Pull Gap curve diagrams are useful when selecting a magnet for a particular tractive or holding application.

Reluctance, R

Reluctance is the resistance in a magnetic circuit and is related to the magnetomotive force, F and magnetic flux (R =F/ magnetic flux) where F is the magnetomotive force.

Remenance

Remenance is the magnetic induction which remains in a magnetic circuit after the removal of an applied magnetizing force. If there is an air gap in the circuit, the remenance will be less than the residual induction Br.

Residual Induction Br

This represents the maximum flux output from a given magnet material measured at the point where the Hysteresis Loop crosses the B axis at zero magnetizing force.

Return Path

A magnetic circuit which provides a low reluctance path for the magnetic flux. Reversible Temperature Coefficient A measure of the reversible changes in flux caused by temperature variations.

Saturation

This is the condition whereby a magnet or ferromagnetic material has reached a maximum value and an increase in the appliance of magnetizing force produces no increase in induction i.e. saturation flux densities for steels range from 16,000 to 20,000 Gauss.

Stabilisation

The process where a magnet is exposed to demagnetizing influences expected to be encountered in operation. The exposure to these demagnetizing influences such as high or low temperatures or external magnetic fields prevents irreversible losses during actual operation.

"We were delighted with the service provided by Eclipse Magnetics; from the initial site survey through to delivery."

Adrian Seeley, Production Supervisor at AB MAURI UK & Ireland

"I cannot begin to tell you how much it has helped our operation, the magnetic filtration unit has been a real problem solver it has surpassed all our expectations. Its cured a 30 year plague!"

Maintenance Manager at EXL Tube (Steel Ventures)

"This technology is economical, reliable and efficient. I believe that magnetic filtration technology is the future."

John Smith, MMTCI

"Magnetic filtration has dramatically cleaned up our fluids and improved the surface finish we can offer. It extracts around 50Kg per day of ferrous waste."

Facilities Manager, Milacron Machines (Sub-Contract Machining)

"We chose Eclipse Magnetics to supply our housed grid because they are a respected and well-established brand. They offered us a very competitive price, and the process of ordering and installation was straightforward and reliable."

Pat Richards, Chief Engineer at Simpsons Malt

“We are delighted with the Automag installation; it’s solved all the problems we were having previously with downtime and maintenance costs. The filter means that we are able to use recycled water, which is saving us £1000 per week!”

Kenneth McRae, Principle Engineer at Vallourec

"Here at Qualflow, we base our business on a philosophy of make the product simple to use, reliable and cost-effective. Eclipse Magnetics’ neodymium magnets offer the strongest magnetic performance, and are nickel plated, making them a cost effective.."

Justin Lawler Ph.D. MBA, Chief Technology Officer at Qualflow Systems Ltd

"The Ultralift Plus magnetic lifter from Eclipse Magnetics is the perfect solution for the pick-up and transportation of the ultrasonic calibration blocks in our facility"

John Crossley, NDT Technology Lead at the Nuclear AMRC

"The result is an aesthetically pleasing system, which is effective in trapping metal contaminants and is easy to clean..."

Ian Aunger at Roquette